Digi DC-190 Instruction Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
Digitronic Digital Cam Switch Unit
Automationsanlagen GmbH CamCon DC190
6.4.2. Offline - Simulation
The Digisoft 2000 Program gives you the opportunity to simulate the encoders like the Measuring
System, hardware inputs (l) and backplane inputs (V) of an S7 (CamCon DC300 or ControlLogix 1756-
DICAM) in the "Offline" programming. This option makes it possible to test a PLC logic program on
your computer without having to install a CamCon or further machinery. This option is not available
"Online". The Digisoft 2000 program can be downloaded at http://www.digitronic.com.
6.5. Cam programming
Cam programming is used to select a program number for the programming of a cam. You can name
any program number (with a tool or recipe number, e.g.). Programmed cams are displayed graphical
on a scale in the resolution of the used measuring system. Maximum and minimum values (actual or
cam values) will be displayed to the left and right above the scale (e.g. 0° - 359°).
You can access the programming options by clicking the "Edit" button.
6.5.1. Entering Cams
The cam programming can be used to address a name to any cam output, to enter or edit the
switching points of the cams, to adjust the Delay Time compensation or to shift all cams of an output or
an output track stepwise.
In addition, the option "Programm Multicams" can be used to fill up a cam track with multiple cams
automatically.
Hint: If you let the cursor hover“ above the green box of a cam, the switching points will be
displayed in a small pop up box.
Version from: 19.04.2012 Page: 30
Page view 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 63 64

Comments to this Manuals