Digi 34 Specifications Page 135

  • Download
  • Add to my manuals
  • Print
  • Page
    / 148
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 134
140 Chapter 9 Pinout reference
DB-25F to DB-25M terminal/printer cable
From
DB-
25
Signal Direction Signal To DB-25
6 DSR
RTS 4
8 DCD
3 RxD
TxD 2
2 TxD
RxD 3
20 DTR
DSR 6
DCD 8
7SG
SG 7
4 RTS
CTS 5
5 CTS
DTR 20
Shell GND
GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
Altpin should be turned off when using this cable.
This cable utilizes the DTR signal of the terminal/printer for hardware flow control (RTS/CTS).
Okidata printers may use SSD (pin 11) instead of DTR (pin 20) on Term/Prn DB25 side of above
diagram. If this is the case, the printer should be set to SSD+.
Page view 134
1 2 ... 130 131 132 133 134 135 136 137 138 139 140 ... 147 148

Comments to this Manuals

No comments