6.7.2.2. SETTING – UP TWO CHANNEL SCALE SX-D PLATFORM
IF YOU ARE SETTING UP A TWO CHANNEL SCALE WITH PLATFORM CONTAINING TWO LOAD
CELLS BUILT –IN, THIS IS THE WAY THE SPECS 16 & 17 SHOULD BE SET.
16
Normally
Set
0 0 0 1
_ _ _ _
SCALE 1:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
SCALE 2:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
17
Normally
Set
1 0 1 1
_ _ _ _
SCALE 3:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
SCALE 4:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
The SX-D Platform Would Be Plugged Into The SX-1 Load Cell Connector.
Using The SX-D Platform In Scale 1 SX-1 Connector No Power Supply Will Be Necessary As Power Will
Be Supplied By The Platform.
In This Case Other Specs That Will Need To Be Set Are As Follows:
Weight and Measures Specification: To enter this mode, enter the numeric keys 1,4,2 while pressing the Re-
zero Key. The Span Switch must be “ON” to enter this mode.
Spec No. Bit 3 Bit 2 Bit 1 Bit 0
20
_ _ _ _
Minimum Display ( Scale 1)
00 : 2 10 : 5
01 : 1 11 : 10 !!
!!
1
Minimum Display (Scale 2)
00 : 2 10 : 5
01 : 1 11 : 10 !!
!!
1
21
_ _ _ _
Weight Decimal Point Position (Scale 1)
000 : 00000 010 : 000.00 100 : 0.0000
001 : 0000.0 011 : 00.000 !!
!!
1
22
_ _ _ _
Weight Decimal Point Position (Scale 2)
000 : 00000 010 : 000.00 100 : 0.0000
001 : 0000.0 011 : 00.000 !!
!!
1
23
Normally
Set
0 0 1 1
Display Resolution
00 : 1/10,000 10 : 1/2,500
!!
!!
1
01 : 1/5,000 11 : Not Used
Zero Setting Range
00 : + Unlimited 10 : +- 10% FS
- 10% FS
01 : +- 2% FS 11 : Not Avail.
25
0 0 0 0
Scale Starting Method
0 : Automatic
1 : Manual
IR Mode
protected by
Span Switch
0 : No 1 : Yes
Scale Type
1 : Double
Scale !2
Gross Mode Available
0 : Yes
1 : No
32
1 0 1 1
Calibration Mode protected
by Span Switch
0 : Yes 1 : No
Battery Low
Lamp
0: Yes 1: No
Auto Exit from
Add Mode
0 : No 1 : Yes
External Load Cell (Scale 3)
0: No
!!
!!
2
33
0 _ _ _
Over Weight Mask at
0 : +1d
1 : +9d
Weight Decimal Point Position (Scale 3)
000 : 00000 010 : 000.00 100 : 0.0000
001 : 0000.0 011 : 00.000
36
_ _ 0 0
Minimum Display ( Scale 3)
00 : 2 10 : 5
01 : 1 11 : 10
A/D Board (For Scale 3)
00 : Normal
01 : Prevent from Small vibration / fast change in display
10 : Prevent from Medium vibration
11 : Prevent from Large slow change in display
!!
!!
1
To Select The Minimum Display And Decimal Location Divide Capacity By The Display Resolution Selected In
Spec23. !!
!!
2 In This Case Scale 1 & 2 Will Be Turned On.