5-4 Configuring Ports for Outgoing/Bi-Directional Connec-
Example
In this example, ports 1 and 2 are set up for incoming modem connections using RTS/CTS flow
control.
set ports range=1-2 dev=min
set line range=1-2 baud=115200
set flow range=1-2 ixon=off ixoff=off cts=on rts=on
Configuring Ports for Outgoing/Bi-Directional Connections: Command Line
This section describes how to configure outgoing and bidirectional modem connections from the
command line.
Related Information
For more information on setting the port’s flow control attributes see the set flow command in
the Digi One/PortServer TS Command Reference.
For information on setting serial line operating parameters such as character size, the number of
stop bits, and parity, see the set line command in the Digi One/PortServer TS Command Refer-
ence.
For more information on configuring dialer and login scripts, see the set script command in the
Digi One/PortServer TS Command Reference.
Before You Begin
This procedure assumes that you
Know the operating parameters required by the modem. If you do not, see the modem documen-
tation.
Have or will correctly cable the connection between the PortServer TS 8/16 serial ports and
modems. See the Digi One/PortServer Cable Guide for more information.
Logged in as root
Procedure
1. Supply a set ports command that specifies the following:
set ports range=range dev=dev
where range is a serial port or range of serial ports and dev is one of the following:
dev=mout for outgoing-only connections
dev=mio for bidirectional connections
Note: Use a group number (on the group field), if you intend to create a hunt group of ports
that can access a pool of modems. Make sure this group number is greater than 65.
Example:
set ports range=2 dev=mio
2. Supply a set line command that specifies the following:
set line range=range baud=bps
where range is a serial port or range of ports and bps is the line speed of the connection
Example:
set line range=2 baud=115200
3. Supply a set flow command that defines the flow control scheme required by the modem.
Example
In this example, ports 1 and 2 are configured for bidirectional modems.
set ports range=1-2 dev=mio
set line range=1-2 baud=115200
set flow range=1-2 ixon=off ixoff=off rts=on cts=on