Configuration through the web interface
112
Test only when idle: if no data is received for the above period of time: Specifies that
the test repeat interval (above) is to be used as an idle period interval. That is, initiate the
selected link integrity test only after no data has been received for the specified interval
of time. This changes the behavior of the test in that the test interval varies according to
the presence of other data received from the mobile connection.
Although using this idle option may result in less data being exchanged over the mobile
connection, it also prevents the link integrity tests from running as often to verify the
true bi-directional state of that connection.
Reset the link after the following number of consecutive link integrity test failures:
Specifies that after the configured number of consecutive link integrity test failures, the
mobile connection should be disconnected and reestablished. This value must be
between 1 and 255. The default is 3. When the mobile connection is reestablished, the
“consecutive failures” counter is reset to zero.
If the mobile connection is disconnected for any reason (including not as a result of a
link integrity test failure), the consecutive failures count is reset to zero when the mobile
connection is reestablished.
Status and statistical information for mobile connections
Once the mobile settings have been configured, you can monitor the status of mobile connections
by going to Administration > System Information > Mobile. See "Mobile information and
statistics" on page 206.
From the command line, this mobile information is displayed by issuing display mobile and
display pppstats commands.