14-pin input/output connector pinouts
Maximum power usage on sensor power lines
A maximum of 300mA can be shared between all 5 24V power taps on the 14-pin connector.
Pin Function
1 +24VDC sensor power
2 GND
3 Analog/Digital Input/Output 1
4 +24VDC sensor power
5 GND
6 Analog/Digital Input/Output 2
7 +24VDC sensor power
8 GND
9 Analog/Digital Input/Output 3
10 +24VDC sensor power
11 GND
12 Analog/Digital Input/Output 4
13 +24VDC for auxiliary power
14 GND for auxiliary power